商鋪名稱:上海朕鋅電氣設(shè)備有限公司
聯(lián)系人:萬紫云(小姐)
聯(lián)系手機:
固定電話:
企業(yè)郵箱:2779823058@qq.com
聯(lián)系地址:上海金山區(qū)楓涇鎮(zhèn)楓灣路500弄113號
郵編:201501
聯(lián)系我時,請說是在線纜網(wǎng)上看到的,謝謝!
西門子銷售中心6ES7331-7KF02-0AB0
西門子銷售中心6ES7331-7KF02-0AB0
西門子銷售中心6ES7331-7KF02-0AB0
滿足不同客戶需求,誠信走天下,走遍天下有朋友西門子PLC代理商 西門子PLC模塊代理商 西門子PLC通訊模塊代理商 西門子PLC模擬量模塊代理商 西門子PLC模塊總代理商西門子變頻器 觸摸屏 代理商
聯(lián)系人:萬紫云(銷售部)
傳真:021-67226033
24小時業(yè)務(wù)咨詢熱線:15021699383
工作QQ:2779823058
電話:021-31668149
我公司只銷售西門子原裝正品,享受西門子免費一年保修
公司網(wǎng)址http://zhenxindianqi.cn/
zx-plc.com )
The SINAMICS G120 frequency inverter is designed to provide precise and cost-effective speed/torque control of three-phase motors.
With different device versions (frame sizes FSA to FSGX) in a power range from 0.37 kW to 250 kW (0.5 hp to 400 hp), it is suitable for a wide variety of drive solutions.
Example: SINAMICS G120, frame sizes FSA, FSB and FSC; each with Power Module, CU240E?2 F Control Unit and Basic Operator Panel BOP-2
Example: SINAMICS G120, frame sizes FSD, FSE and FSF; each with Power Module, CU240E?2 F Control Unit and Intelligent Operator Panel IOP
Example: SINAMICS G120, frame size FSGX; with Power Module, CU240E?2 F Control Unit and Basic Operator Panel BOP-2
SINAMICS G120 is a modular inverter system that essentially comprises two function units:
The Control Unit controls and monitors the Power Module and the connected motor using several different closed-loop control types that can be selected. It supports communication with a local or central controller and monitoring devices.
The Power Module supplies the motor in the power range 0.37 kW to 250 kW (0.5 hp to 400 hp). It features state-of-the-art IGBT technology with pulse-width-modulated motor voltage and selectable pulse frequency. Comprehensive protection functions provide a high degree of protection for the Power Module and the motor.
The Control Units can be combined with the following Power Modules:
Control Units
Power Modules degree of protection IP20
PM240?2
PM240
PM250
CU230P?2
?
?
?
CU240E?2
?
?
?
CU250S?2
?
?
?
SINAMICS G120 standard inverters are available in different versions for safety-related applications. The PM240?2 and PM250 Power Modules are already designed for Safety Integrated. PM240 Power Modules, frame size FSGX (i.e. 160 kW/250 hp and higher) are approved only for the Basic Safety functions (STO, SS1, and SBC). A drive can be combined with a Control Unit with safety functions (see overview) in order to create a Safety Integrated drive. The availability of Safety Integrated functions depends on the type of Control Unit.
Control Unit
Basic Safety functions
Extended Safety functions
STO
SS1
SBC 1)
SLS
SDI
SSM
CU230P?2
–
–
–
–
–
–
CU240E?2
?
–
–
–
–
–
CU240E?2 F
?
?
–
?
?
? 2)
CU250S?2
?
?
?
? 3)
? 3)
? 3)
1) The SBC function can be utilized only if a Safe Brake Relay is installed.
2) SSM possible only for CU240E?2 DP?F / CU240E?2 PN?F Control Units with PROFIsafe.
3) With license for Extended Safety functions.
Basic Safety functions (certified according to IEC 61508 SIL 2, and EN ISO 13849?1 PL d and Category 3)
Extended Safety functions (certified according to IEC 61508 SIL 2 and EN ISO 13849?1 PL d and Category 3)
Basic Safety and Extended Safety functions can be activated via PROFIsafe or by means of the safety inputs.
None of the safety functions require a motor encoder and they are thus cheaper and easier to implement. Existing systems in particular can be simply updated with safety technology without the need to change the motor or mechanical system.
The Safe Torque Off (STO) function can be used without restriction for all applications. The SS1, SLS, SSM and SDI functions are only permissible for applications where the load can never accelerate when the inverter is switched off. They are therefore not permitted for applications involving pull-through loads such as hoisting gear and unwinders.
Additional information is provided in chapter Highlights, section Safety Integrated.
The innovative Efficient Infeed Technology is employed in PM250 Power Modules. This technology allows the energy produced by motors operating in generator mode connected to standard inverters to be fed back into the supply system. For control cabinets, an additional temperature rise can be avoided and the amount of space required can be reduced due to the fact that components such as braking resistors, braking choppers and line reactors can be eliminated. Further, wiring and engineering costs are significantly reduced. At the same time, energy consumption can be reduced and ongoing operating costs noticeably reduced.
Additional information is provided in chapter Highlights, section Efficient Infeed Technology.
The new cooling system and varnishing of the electronic modules significantly increases the service life or useful life of the device.
Integrated technologies help when optimizing the energy usage of the plant or system referred to the particular application:
Additional information is provided in chapter Highlights, section Energy efficiency.
SINAMICS G120 standard inverters are modular inverters for standard drives. Selection of the SINAMICS G120 is reduced to two or three steps thanks to the modular system used.
The optimum Control Unit is selected first, based on the number of I/Os and any additional functions required such as Safety Integrated or HVAC. The communication options are already integrated and do not have to be additionally ordered or plugged in. Three product series are available corresponding to the particular application.
CU230P?2 Control Units
The CU230P?2 Control Units have been specifically designed for pump, fan and compressor applications.
Control Unit CU240E?2
The CU240E?2 Control Unit is suitable for a wide range of applications in general machine construction, such as conveyor belts, mixers and extruders.
CU250S?2 Control Units
The CU250S?2 Control Units are suitable for applications involving single drives with exacting speed control requirements such as extruders and centrifuges, and for positioning tasks such as conveyor belts, lifting/lowering devices, etc. They can also be used to implement multi-motor drives without DC coupling such as wire-drawing machines and simple material lines.
Description
Fieldbus
Profile
Inputs
Integrated safety technology
Fail-safe
Control Unit
Article No.
CU230P?2 series - the specialist for pumps, fans, compressors, water, buildings
Technology functions (selection): Free function blocks (FFB), 4 × PID controller, cascade connection, hibernation mode, essential service mode, multi-zone control
CU230P?2 HVAC
–
6 DI
3 DO
–
–
6SL3243-0BB30-1HA3
CU230P?2 DP
6SL3243-0BB30-1PA3
CU230P?2 PN
6SL3243-0BB30-1FA0
–
CU240E?2 series – for standard applications in general machinery construction, such as conveyor belts, mixers and extruders – without encoder
Technology functions (selection): Free function blocks (FFB), 1 × PID controller, motor holding brake
CU240E?2
–
6 DI
3 DO
STO
1 F-DI
6SL3244-0BB12-1BA1
CU240E?2 DP
6SL3244-0BB12-1PA1
CU240E?2 PN
6SL3244-0BB12-1FA0
–
CU240E?2 F
–
STO, SS1, SLS, SDI
3 F-DI
6SL3244-0BB13-1BA1
CU240E?2 DP?F
STO, SS1, SLS, SSM 1), SDI
6SL3244-0BB13-1PA1
CU240E?2 PN?F
6SL3244-0BB13-1FA0
–
CU250S?2 series – for complex applications such as extruders and centrifuges – with and without encoder (basic positioner (EPos) optional)
Technology functions (selection): Free function blocks (FFB), 1 × PID controller, motor holding brake
CU250S?2
–
11 DI
3 DO
4 DI/DO (DI can be used as high-speed inputs)
STO, SBC, SS1
3 F-DI
1 F-DO
6SL3246-0BA22-1BA0
CU250S?2 DP
6SL3246-0BA22-1PA0
CU250S?2 PN
6SL3246-0BA22-1FA0
–
CU250S?2 CAN
–
6SL3246-0BA22-1CA0
1) SSM is possible only with PROFIsafe.
Description
Suitable for
Article No.
SINAMICS SD card
512 MB + firmware V4.7 SP6 (Multicard V4.7 SP6)
CU230P?2
6SL3054-7TD00-2BA0
Description
SINAMICS SD card
SINAMICS SD card
Licenses (without SD card)
Article No.
Article No.
Article No.
License Extended Functions
6SL3054-4AG00-2AA0-Z
E01
6SL3054-7TD00-2BA0-Z
E01
6SL3074-7AA04-0AA0
License Extended Functions
6SL3054-4AG00-2AA0-Z
F01
6SL3054-7TD00-2BA0-Z
F01
6SL3074-0AA10-0AA0
Licenses Extended Functions
6SL3054-4AG00-2AA0-Z
E01+F01
6SL3054-7TD00-2BA0-Z
E01+F01
–
For additional information about firmware V4.7 SP6:
https://support.industry.siemens.com/cs/document/109482094
Description
Suitable for
Article No.
SINAMICS SD card
512 MB + firmware V4.6 (Multicard V4.6)
SIEMENS上海朕鋅公司(西門子授權(quán)一級代理商)
西門子代理商公司-上海朕鋅電氣設(shè)備有限公司本著“以人為本、科技先導(dǎo)、顧客滿意、持續(xù)改進”的工作方針,致力于工業(yè)自動化控制領(lǐng)域的產(chǎn)品開發(fā)、工程配套和系統(tǒng)集成
概述
Operator-friendly design
Safety Integrated
to protect against active movement of the drive
for continuous monitoring of a safe braking ramp
brake. When enabled, SBC is always activated at the same time as STO. The Safe Brake Relay is used for SBC.
for protection against dangerous movements on exceeding a speed limit
This function ensures that the drive can only rotate in the selected direction.
This function signals if a drive operates below a specific speed/feed velocity.
Efficient Infeed Technology
Innovative cooling concept and varnishing of electronic modules
Energy efficiency
優(yōu)勢
Integrated are, e.g.:
設(shè)計
Application-orientated design of SINAMICS G120
Selecting the Control Unit
The CU230P?2 is the Control Unit for the pump, fan and compressor inverters SINAMICS G120P and SINAMICS G120P Cabinet. Detailed information can be found in Catalog D 35.
Outputs
digital inputs
digital outputs
4 AI
2 AO
2 AI
2 AO
(opt. for each 2 DI)
(opt. for each 2 DI)
2 AI
2 AO
(opt. for each 2 DI)
(opt. for each 2 DO)
Optional memory card with firmware V4.7 SP6 for CU230P?2, CU240E?2 and CU250S?2 Control Units
CU240E?2
CU250S?2
Optional memory cards with licenses for CU250S?2 Control Units only
512 MB + licenses
512 MB + firmware V4.7 SP6 (Multicard V4.7 SP6) + licenses
for upgrading license
of an existing SD card
Basic positioner (EPos)
Safety (SLS, SSM, SDI)
Basic positioner (EPos) + Safety (SLS, SSM, SDI)
Optional memory cards with firmware V4.6 or V4.7 for existing installations when service is required